{"id":1887,"date":"2020-07-06T08:26:52","date_gmt":"2020-07-06T08:26:52","guid":{"rendered":"https:\/\/www.mr-electric.co.uk\/cornwall\/?p=1887"},"modified":"2020-07-06T08:26:52","modified_gmt":"2020-07-06T08:26:52","slug":"new-fire-regulations-for-landlords-tenants","status":"publish","type":"post","link":"https:\/\/www.mr-electric.co.uk\/cornwall\/new-fire-regulations-for-landlords-tenants\/","title":{"rendered":"NEW FIRE REGULATIONS FOR LANDLORDS &amp; TENANTS"},"content":{"rendered":"<h3 style=\"text-align: center\"><strong>RENTED PROPERTIES:\u00a0\u00a0<\/strong><\/h3>\n<p>In-line with recent changes to The Domestic Fire Alarm Regulations [BS 5839 Part 6\u00a0&#8211;\u00a02019]\u00a0<strong>all<\/strong> rental properties now come under a higher detection level requirement than\u00a0ever\u00a0before.<\/p>\n<p>It is not retrospective, so property owners don\u2019t have to upgrade their system to the latest regulations.<\/p>\n<h3 style=\"text-align: left\"><b>UNLESS:<\/b><\/h3>\n<ol>\n<li>They would like to make sure the property is up to the latest fire regulations and is as safe as it can be for their tenants.<\/li>\n<li>If the property was majorly altered or rewired,\u00a0for example,\u00a0where notification to the local Council would be required. It would then have to be upgraded to the relevant grade.<\/li>\n<\/ol>\n<h3 style=\"text-align: left\"><b>Holiday Lets [properties with short-term paying guests<\/b><b>]<\/b><b>:\u00a0<\/b><\/h3>\n<p style=\"text-align: left\">These would be a Grade D1 system, Category LD1 (j)<\/p>\n<h3 style=\"text-align: left\"><b>Rental Properties:\u00a0<\/b><\/h3>\n<p style=\"text-align: left\"><b>\u00a0<\/b>These would be a Grade D1 system, Category LD2(d)<\/p>\n<p>Below is an Extract from the British Standard [BS5839 Part 6] 2019:<\/p>\n<p><img loading=\"lazy\" class=\"alignnone wp-image-1901 size-full\" src=\"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-06-at-08.50.43.png\" alt=\"\" width=\"1444\" height=\"204\" srcset=\"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-06-at-08.50.43.png 1444w, https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-06-at-08.50.43-300x42.png 300w, https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-06-at-08.50.43-768x108.png 768w, https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-06-at-08.50.43-1024x145.png 1024w, https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-06-at-08.50.43-616x87.png 616w, https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-06-at-08.50.43-853x121.png 853w\" sizes=\"(max-width: 1444px) 100vw, 1444px\" \/><\/p>\n<p>As you can see there is an Annex J &amp; D, which is defined below.<\/p>\n<p>J) Detectors may normally be omitted from roof voids unless there are specific significant fire hazards such as gas boilers or electrical equipment for photovoltaic systems.<\/p>\n<p>d) Heat detectors should be installed in every kitchen and a\u00a0smoke detector should be installed in\u00a0the principal habitable room. Where more than one room might be used as the principal\u00a0habitable room, a smoke detector should be\u00a0 installed in each of these rooms.<\/p>\n<h3 style=\"text-align: center\"><b>DETAIL ON GRADE &amp; CATEGORY<\/b><b>:<\/b><\/h3>\n<p><b>GRADE D1<\/b><b>:\u00a0<\/b>A system of one or more mains powered detectors, each with a tamper-proof\u00a0standby supply consisting of a battery or batteries.<\/p>\n<p><b>GRADE D2<\/b><b>:\u00a0<\/b>A system of one or more mains powered detectors, each with an integral\u00a0standby supply consisting of a user-replaceable battery or batteries.<\/p>\n<h3 style=\"text-align: center\"><b>LD1<\/b><br \/>\nHigh Protection<\/h3>\n<p style=\"text-align: left\"><b>All areas where a fire could start,\u00a0<\/b><b>e.g.<\/b><b>:<\/b><\/p>\n<p><img loading=\"lazy\" class=\"wp-image-1897 aligncenter\" src=\"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-05-at-23.22.54-300x207.png\" alt=\"\" width=\"250\" height=\"173\" srcset=\"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-05-at-23.22.54-300x207.png 300w, https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-05-at-23.22.54-616x426.png 616w, https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-05-at-23.22.54.png 718w\" sizes=\"(max-width: 250px) 100vw, 250px\" \/><\/p>\n<ul>\n<li style=\"text-align: left\"><b><\/b>Hallways<\/li>\n<li style=\"text-align: left\">Landings<\/li>\n<li style=\"text-align: left\">Living Room<\/li>\n<li style=\"text-align: left\">Kitchen<\/li>\n<li style=\"text-align: left\">Bedrooms<\/li>\n<li style=\"text-align: left\">Airing cupboards\/ Meter cupboards<\/li>\n<\/ul>\n<h3><\/h3>\n<h3 style=\"text-align: center\"><strong>LD2<\/strong><br \/>\n<strong>Medium Protection<\/strong><\/h3>\n<p><b>Escape routes and high-risk areas, e.g.<\/b><\/p>\n<p><img loading=\"lazy\" class=\"wp-image-1892 alignright\" src=\"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-05-at-23.11.38-300x208.png\" alt=\"\" width=\"277\" height=\"193\" srcset=\"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-05-at-23.11.38-300x208.png 300w, https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-05-at-23.11.38-616x428.png 616w, https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-05-at-23.11.38-730x507.png 730w, https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-05-at-23.11.38.png 760w\" sizes=\"(max-width: 277px) 100vw, 277px\" \/><\/p>\n<ul>\n<li>Hallways<\/li>\n<li>Landings<\/li>\n<li>Kitchen<\/li>\n<li>Living Room<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3 style=\"text-align: center\"><b>Carbon Monoxide \u2013 British Standard BS EN 50292:2013<\/b><b>:<\/b><\/h3>\n<p>Carbon Monoxide is a silent killer, you can\u2019t see it, smell it or taste it.<\/p>\n<p>This is why having Carbon Monoxide alarms installed throughout a property is so important.<\/p>\n<p>The British Standard BS EN 50292:2013 offers recommendations on the installation and maintenance of Carbon Monoxide alarms.<\/p>\n<p>The standard states that a Carbon Monoxide alarm should be fitted in:<\/p>\n<p><img loading=\"lazy\" class=\"wp-image-1894 alignright\" src=\"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-05-at-23.20.06-300x195.png\" alt=\"\" width=\"297\" height=\"193\" srcset=\"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-05-at-23.20.06-300x195.png 300w, https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-05-at-23.20.06-616x401.png 616w, https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-05-at-23.20.06.png 620w\" sizes=\"(max-width: 297px) 100vw, 297px\" \/><\/p>\n<ul>\n<li>Rooms that have any fuel burning appliances \u2013 such as an open fire, gas cooker or boiler.<\/li>\n<li>Rooms where people spend the most time \u2013 such as a living room.<\/li>\n<li>Rooms where people sleep.<\/li>\n<li>Any room that has a flue running through it.<\/li>\n<\/ul>\n<p>This means that a Carbon Monoxide leak can be detected from all the potential sources and heard throughout the property.<\/p>\n<p>That number of CO alarms are generally not installed, so if you have a limited number of alarms then you should look to cover the areas that are at highest risk including:<\/p>\n<p><img loading=\"lazy\" class=\"size-medium wp-image-1895 alignright\" src=\"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-05-at-23.20.16-300x204.png\" alt=\"\" width=\"300\" height=\"204\" srcset=\"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-05-at-23.20.16-300x204.png 300w, https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-05-at-23.20.16-616x418.png 616w, https:\/\/www.mr-electric.co.uk\/cornwall\/wp-content\/uploads\/sites\/12\/2020\/07\/Screenshot-2020-07-05-at-23.20.16.png 654w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<ul>\n<li>Rooms with a flueless or open-flued appliances such as an open fire, gas cooker or portable heater \u2013 these would leak carbon monoxide?directly into the room producing the greatest risk.<\/li>\n<li>Rooms where the occupants spend the most time \u2013 this is to ensure that they are protected to any carbon monoxide exposure in these areas and hear the alarm as soon as possible.<\/li>\n<li><strong style=\"text-align: center\">This can be best achieved by linking to the Smoke\/Heat detection system.\u00a0<\/strong><\/li>\n<\/ul>\n<h3 style=\"text-align: center\"><strong>If you need further information or would like one of our Technicians to visit and carry out a free Fire Detection test, please contact us.<\/strong><\/h3>\n","protected":false},"excerpt":{"rendered":"<p>RENTED PROPERTIES:\u00a0\u00a0 In-line with recent changes to The Domestic Fire Alarm Regulations [BS 5839 Part 6\u00a0&#8211;\u00a02019]\u00a0all rental properties now come under a higher detection level requirement than\u00a0ever\u00a0before. It is not retrospective, so property owners don\u2019t have to upgrade their system to the latest regulations. UNLESS: They would like to make sure the property is up [&hellip;]<\/p>\n","protected":false},"author":24,"featured_media":1886,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[10,52],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-json\/wp\/v2\/posts\/1887"}],"collection":[{"href":"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-json\/wp\/v2\/users\/24"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-json\/wp\/v2\/comments?post=1887"}],"version-history":[{"count":16,"href":"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-json\/wp\/v2\/posts\/1887\/revisions"}],"predecessor-version":[{"id":1912,"href":"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-json\/wp\/v2\/posts\/1887\/revisions\/1912"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-json\/wp\/v2\/media\/1886"}],"wp:attachment":[{"href":"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-json\/wp\/v2\/media?parent=1887"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-json\/wp\/v2\/categories?post=1887"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mr-electric.co.uk\/cornwall\/wp-json\/wp\/v2\/tags?post=1887"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}